Webro 16/2 Speaker Cable, 2 Core 16AWG (1.31mm²) LSNH Violet

Webro 16/2 Speaker Cable, 2 Core 16AWG (1.31mm²) LSNH Violet

10m
£15
Skip to product information
Webro 16/2 Speaker Cable, 2 Core 16AWG (1.31mm²) LSNH Violet

Webro 16/2 Speaker Cable, 2 Core 16AWG (1.31mm²) LSNH Violet

£15 £12.50 ex VAT
Length
Order by 1pm Mon–Fri for same-day dispatch
Tracked UK delivery £7.99, free over £50 · Next day £11.99
30-day returns · full manufacturer warranty

Webro 16/2 Speaker Cable is an installation cable with 99.999% oxygen-free plain copper conductors, designed for permanent routing to in-ceiling or in-wall speakers. It suits anyone wiring a single speaker per cable run, whether for a two-channel system or a multi-room setup, and is supplied with a low smoke, non-halogen sheath for safer fixed installation.

Why we like it

  • 99.999% oxygen-free plain copper conductors for reliable signal transfer
  • Low Smoke Non-Halogen (LSNH) insulation and sheath, built for fixed installation
  • UKCA CPR classification Eca to BS EN 50575, with flame retardancy to BS EN 60332-1-2
  • Low smoke emission (BS EN 61034-2) and low halogen gas release (BS EN 60754-1&2)
  • Supplied cut to length from the drum, so you only buy the length you need

Good to know

This is a 2-core cable, so you'll need one cable run per speaker; if you're wiring a stereo pair or two speakers from a single source point, a 4-core cable would let you carry both channels on one run instead. At 16AWG, this gauge is well suited to typical domestic cable runs. For longer runs, 14AWG is generally recommended, and for very long runs or low-impedance, high-power home cinema setups, 12AWG is the better choice. As an Eca-rated, LSNH cable, it's designed for fixed installation within walls and ceilings rather than for use with portable or exposed wiring. It's available cut to length from the drum in 10m, 20m, 30m or 50m lengths.

Specifications

Brand Webro
Cores 2 (2-core, red/black)
Conductor size 16AWG (1.31mm²)
Stranding 65/0.16mm
Overall diameter 6.1mm ±0.2mm
Conductor DC resistance ≤13.3 Ω/km
Conductor material 99.999% oxygen-free plain copper
Insulation and sheath Low Smoke Non-Halogen (LSNH), violet sheath
CPR classification Eca to BS EN 50575 (UKCA)
Flame retardancy BS EN 60332-1-2
Low smoke BS EN 61034-2
Halogen gas BS EN 60754-1&2
Voltage rating 300/300V
Temperature range (fixed) -20°C to +70°C
Bend radius 15 x overall diameter
Compliance RoHS 3 and REACH compliant
Supply format Cut to length from the drum (10m, 20m, 30m or 50m)

You may also like